Body Fluid Culture*

Important Note

*This test is orderable in Cerner as Body Fluid Culture

Specimen Requirements

  • Specimen Type: Abdominal, amniotic, ascites, bile, joint, paracentesis, pericardial, peritoneal, pleural, synovial, thoracentesis
  • Container/Tube: Anaerobic transport jar/vial or sterile container
  • Specimen Volume: ≥1 mL
  • Specimen Minimum Volume: 0.5 mL
  • Collection Instructions: 
  1. Aseptically obtain fluid via percutaneous needle aspiration or surgery.
  2. Transfer aspirated fluid to anaerobic device or sterile container.
  3. NEVER submit a swab dipped in fluid

Specimen Transport Temperature

Ambient

Reference Values

No growth.  Identification of pathogens

Day(s) Performed

Daily

Analytical Time:

3 days

Performing Laboratory

Rutland Regional Medical Center Laboratory

Methodology

Manual

Test Classification and CPT Coding

  • CPT: 87070- Culture, 87205-Gram stain