Sign in →

Test Code FRFIT Rabies Antibody Endpoint

Important Note

* This test is orderable in Cerner as Rapid Fluorescent Focus Inhib Test-Mayo


Specimen Required


Specimen Type: Serum

Container/Tube: Red

Specimen Volume: 2 mL

Collection Instructions: Draw blood in a plain red-top tube(s), Spin down and send 2 mL of serum refrigerated in a plastic vial.

 

Note:  1. Serum gel tube is acceptable, but must be poured off into plastic vial.

          2. Collection date is required.


Method Name

Serum Neutralization Fluorescent Antibody

Reporting Name

Rabies RFFIT Endpoint, S

Specimen Type

Serum

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  60 days

Reference Values

Reportable range is 0.1 to 15.0 IU/mL

Less than 0.1 IU/mL: Below detection limit

 

In humans a results of 0.5 IU/mL or higher is considered an acceptable response to rabies vaccination according to the World Health Organization (WHO) guidelines; see WHO and Advisory Committee on Immunization Practices documents for additional guidance.

 

Day(s) Performed

Monday, Wednesday, Thursday

Report Available

21 to 35 days

Performing Laboratory

RFFIT/K-State Rabies Laboratory Manhattan/K-State Innovation Center

CPT Code Information

86382

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FRFIT Rabies RFFIT Endpoint, S 6524-3

 

Result ID Test Result Name Result LOINC Value
Z2071 Rabies Titer-Response 6524-3