Esophageal Brush for Cytologic Examination
Methodology
ThinPrep and Conventional Microscopic Evaluation, Pap and MGG Stain
Performing Laboratory
Rutland Regional Medical Center, Cytopathology
Specimen Requirements
Brush from Endoscopy
Specimen Collection and Transport
- Label at least two (2) glass microscope slides with two (2) unique patient identifiers.
- Collect brush specimen
- Starting at frosted end of a glass microscope slide, place brush on slide and roll brush away from frosted end of slide, streaking material. Immediately fix the slide with spray fixative or immerse in 95% ethanol.
- Repeat step 3 for second slide but do NOT fix this slide. Allow it to air dry.
- Remove brush head and place into a 50mL conical tube containing 30 mL of CytoLyt® fluid.
Stable at Room Temperature.
If collected after hours, please refrigerate brush head in CytoLyt® fluid
Day(s) Performed
Monday to Friday; 7:00AM to 4:30PM
Available as STAT
Test Classification and CPT Coding
CPT 88112 or 88104