Panorama-Horizon Kit Test*
Performing Laboratory
Natera, Inc,
Specimen Requirements
Specimen Type: Blood
Container/Tube: Cell-Free DNA BCT and Lavendar top
Specimen Volume: Fill two "tiger" top Streck tubes and one Lavendar tube with 10 mL
Order Verification: Check requisition to confirm Panorama and Horizon Panels are ordered:
Collection Instructions:
1. Do not utilize butterfly needles for collections.
2. Collect 10 mL in each tube and gently invert tubes at least 10 times
3. Record time of collection and username on Cerner labels.
4. Utilize Cerner label and attach to tubes.
5. Do not cover 2D barcode on tubes with the Cerner.
4. Record collection date/time on large Cerner label and include with Kit.
Specimen Transport Temperature
Ambient
Day(s) Performed
Sunday through Saturday
Kit Reordering Information
Additional Kits can be ordered from Natera, Inc Support:
844.778.4700
Specimen Transport Instructions
1. Kit must include completed requisition, Large Cerner label, and tubes
2. Complete Date of Sample Collection on requisition:
3. Place included Panorama 2D barcode label on top right corner of requisition.
Specimen Stability
5 days